"Error: SCSI-3 PR operation failed" reported when importing disk groups via Veritas cluster in AIX with EMC Powerpath

book

Article ID: 100002855

calendar_today

Updated On:

Description

Error Message

VCS ERROR V-16-10011-705 (pacr-srv-utdb07) DiskGroup:MMCtestdg:online:** ERROR: vxdg import failed on Disk Group MMCtestdg after vxdctl enable


VCS INFO V-16-2-13001 (pacr-srv-utdb07) Resource(MMCtestdg): Output of the completed operation (online)


VxVM vxdg ERROR V-5-1-10978 Disk group MMCtestdg: import failed:
SCSI-3 PR operation failed

Applies To

OS: IBM AIX: 5.3
EMC SW: PowerPath 5.3 
Host Level Protection: Host Clustering: VCS 5.3 MP3 
Product: Symmetrix
Problem: A reservation is placed on a LUN and then cleared, which results in a return value of 16 in a VCS cluster.

 

Cause

The issue occurs as EMC PowerPath fails to handle the status of a clear reservation SCSI command correctly.

Resolution

This issue is addressed in the following EMC PowerPath HotFix.

Solution: EMC PowerPath 5.3 HF 01 for AIX

This hotfix includes the following fix:

  • Clearing a reservation on a LUN in a VCS cluster results in clearing the reservation but throws an error return 16 where 0 is expected. This results in not being able to import a disk group.
     

Issue/Introduction

When attempting to import disk groups via Veritas cluster in AIX with EMC Powerpath 5.1 OR 5.3, varying problems are reported for Veritas volume group.