Description

Error Message

I/O error occured on Path c2t500507680120441Dd1s2 belonging to Dmpnode c2t5005076801204251d1s2
Disabled Path c2t500507680120441Dd1s2 belonging to Dmpnode c2t5005076801204251d1s2
SCSI error occured on Path c2t500507680120441Dd1s2: opcode=0x12 reported transport failure (status=0x0, key=0x0, asc=0x0, ascq=0x0)

Cause

The issue was traced to a bad LUN.

Resolution

After checking for the latedst ASL and APM for the IBM SANVC available in The errors stopped after moving the volumes and fiile systems to a different LUN.


Applies To

Solaris 10 running Veritas Volume Manager 5.0 MP3RP2, IBM SANVC

Issue/Introduction

Under heavy write load, SCSI error 0x12 leads to a disabled DMP paths, disabled DMP node, and eventually a disabled file system.