WAC resource is not able to come online.

book

Article ID: 100006951

calendar_today

Updated On:

Description

Error Message

The following error message is seen in Process_A.log at %VCS_HOME%/log

VCS ERROR V-16-10051-6532 Process:wac:monitor:Failed to launch the program 'C:\Program Files\Veritas\Cluster Server\bin\wac.exe'. Error = 193.
 

VCS ERROR V-16-10051-6532 Process:wac:monitor:Failed to launch the program 'C:\Program Files\Veritas\Cluster Server\bin\wacmonitor.exe'. Error = 193.

VCS ERROR V-16-10051-6532 Process:wac:offline:Failed to launch the program 'C:\Program Files\Veritas\Cluster Server\bin\wacstop.exe'. Error = 193.

 

Further, when attempting to start the wac.exe manually, it will report the error below in wac_A.log

VCS ERROR V-16-1-51060 VCS engine rejected connection request from wide area connector because group ClusterService is not properly configured

Cause

A file or folder named Program is present at C:\

Resolution

To address this issue, remove or rename any file or folder named Progam under C:\

Attempt to online the WAC resource and it should now be successful.

 

 

Issue/Introduction

For Veritas Cluster Server (VCS), the Wide-Area-Connector (WAC) resource is not able to come online.