ERROR V-16-1-10113:VCS ERROR V-16-1-10113 System ppapp-domain0 (Node '0') is in DDNA Membership - Membership: 0x6, Visible: 0x0.ERROR V-16-1-10113:VCS ERROR V-16-1-10113 System ppapp-domain0 (Node '0') is in DDNA Membership - Membership: 0x6, Visible: 0x0.
Nov 10 13:14:05 ppapp-domain0 su: [ID 810491 auth.crit] 'su root' failed for barjunan on /dev/pts/7
Nov 10 21:55:20 ppapp-domain0 picld[463]: [ID 528179 daemon.error] WARNING : HIGH TEMPERATURE DETECTED 105, CPU3_DIE_TEMPERATURE_SENSOR
Nov 10 21:56:15 ppapp-domain0 picld[463]: [ID 691918 daemon.error] FSP_GEN_FAULT_LED has turned ON
Nov 10 22:00:03 ppapp-domain0 picld[463]: [ID 528179 daemon.error] WARNING : HIGH TEMPERATURE DETECTED 106, CPU3_DIE_TEMPERATURE_SENSOR
Nov 10 22:04:47 ppapp-domain0 picld[463]: [ID 528179 daemon.error] WARNING : HIGH TEMPERATURE DETECTED 107, CPU3_DIE_TEMPERATURE_SENSOR
Nov 10 22:09:32 ppapp-domain0 picld[463]: [ID 528179 daemon.error] WARNING : HIGH TEMPERATURE DETECTED 108, CPU3_DIE_TEMPERATURE_SENSOR
Nov 10 22:13:20 ppapp-domain0 picld[463]: [ID 528179 daemon.error] WARNING : HIGH TEMPERATURE DETECTED 106, CPU2_DIE_TEMPERATURE_SENSOR
Nov 10 22:17:24 ppapp-domain0 picld[463]: [ID 690822 daemon.error] CRITICAL : HIGH TEMPERATURE DETECTED 109, CPU3_DIE_TEMPERATURE_SENSOR
Nov 10 22:18:32 ppapp-domain0 gab: [ID 397130 kern.notice] GAB INFO V-15-1-20032 Port d closed
Nov 10 22:23:51 ppapp-domain0 gab: [ID 397130 kern.notice] GAB INFO V-15-1-20032 Port u closed
Nov 10 22:23:51 ppapp-domain0 gab: [ID 397130 kern.notice] GAB INFO V-15-1-20032 Port w closed
Nov 10 22:23:51 ppapp-domain0 syseventd[432]: [ID 661968 daemon.error] Daemon restarted
Nov 10 22:24:13 ppapp-domain0 gab: [ID 397130 kern.notice] GAB INFO V-15-1-20032 Port h closed
Nov 11 08:55:26 ppapp-domain0 genunix: [ID 540533 kern.notice] ^MSunOS Release 5.10 Version Generic_144488-17 64-bit
The cause of the shutdown was due to Solaris's Environmental Monitoring feature. For further information, refer to:
docs.oracle.com/cd/E19095-01/sfv890.srvr/817-5950-11/890-troubleshooting.html
Temperature sensors are located throughout the system to monitor the ambient temperature of the system and the temperature of each CPU. The monitoring subsystem frequently polls each sensor and uses the sampled temperatures to report and respond to any overtemperature or undertemperature conditions.
The hardware and software together ensure that the temperatures within the enclosure do not stray outside predetermined “safe operation” ranges. If the temperature observed by a sensor falls below a low-temperature warning threshold or rises above a high-temperature warning threshold, the monitoring subsystem software generates a Warning message to the system console. If the temperature exceeds a low-temperature or high-temperature critical threshold, the software issues a Critical message and proceeds to gracefully shut down the system. In both cases, the System Fault and Thermal Fault LEDs on the front status panel are illuminated to indicate the nature of the problem.
VCS may or may not treat the graceful shutdown as a fault, depending on configuration and state at the time.
Note: Output from the prtpicl -v command shows the high-temperature critical threshold for each component. See the prtpicl man page for information.
Applies To
Solaris 10
5.1SP1