1 Mar 12 16:59:18 server1 vxdmp: [ID 382146 kern.notice] NOTICE: VxVM vxdmp V-5-0-112 [Warn] disabled path 32/0x260 belonging to the dmpnode 258/0x68 due to path failure
2 Mar 12 17:00:50 server1 vxdmp: [ID 382146 kern.notice] NOTICE: VxVM vxdmp V-5-0-112 [Warn] disabled path 32/0x3f0 belonging to the dmpnode 258/0x10 due to path failure
3 Mar 12 17:00:50 server1 vxdmp: [ID 382146 kern.notice] NOTICE: VxVM vxdmp V-5-0-112 [Warn] disabled path 32/0x400 belonging to the dmpnode 258/0x18 due to path failure
Vxdmp marks a path as "disabled" in response to fatal SCSI errors that are received while sending I/O to that path.
1. Review the following logs:
Mon Mar 12 13:23:17.898: SCSI error occured on Path c6t5006048452A6925Cd9s2: opcode=0x12 reported scsi transport error (status=0x0, key=0x0, asc=0x0, ascq=0x0) Mon Mar 12 13:23:17.898: SCSI error occured on Path c6t5006048452A6925Cd32s2: opcode=0x12 reported scsi transport error (status=0x0, key=0x0, asc=0x0, ascq=0x0) Mon Mar 12 13:23:17.898: SCSI error occured on Path c6t5006048452A6925Cd3s2: opcode=0x12 reported scsi transport error (status=0x0, key=0x0, asc=0x0, ascq=0x0) Mon Mar 12 13:23:17.898: SCSI error occured on Path c6t5006048452A6925Cd30s2: opcode=0x12 reported scsi transport error (status=0x0, key=0x0, asc=0x0, ascq=0x0) Mon Mar 12 13:23:17.898: SCSI error occured on Path c6t5006048452A6925Cd62s2: opcode=0x12 reported scsi transport error (status=0x0, key=0x0, asc=0x0, ascq=0x0) Mon Mar 12 13:23:17.898: SCSI error occured on Path c6t5006048452A6925Cd12s2: opcode=0x12 reported scsi transport error (status=0x0, key=0x0, asc=0x0, ascq=0x0) Mon Mar 12 13:23:17.898: SCSI error occured on Path c6t5006048452A6925Cd10s2: opcode=0x12 reported scsi transport error (status=0x0, key=0x0, asc=0x0, ascq=0x0) |
2. Check for unlabeled disks. Unabled disks may cause the DMP probe idle LUN functionality to mark the path as disabled. Examples of disk labels include SMI and EFI.
3. Prior to 5.0 MP3, the error may be triggered by arrays returning unexpected responses to the dmp_probe_idle_lun events. If it is confirmed that there are no underlying problems with the SAN, dmp_probe_idle_lun can be disabled to prevent nuisance errors.
More details about dmp_probe_idle_lun can be found in this article:
SCSI Errors Caused By Idle LUN Probing
https://supportinfoscale.cloud.com/support-home/kbsearch/article?articleNumber=100021774&articleTitle=scsi-errors-caused-by-idle-lun-probing&
"V-5-0-112 [Warn] disabled path 32/0x260 belonging to the dmpnode 258/0x68 due to path failure" is reported by vxdmp