VxVM 5.0 - Problem during IBM SANVC node addition and removal

book

Article ID: 100015398

calendar_today

Updated On:

Description

Error Message

Application and Veritas File System may experience I/O error during IBM SANVC node addition and removal. 

In the /etc/vx/dmpevents.log, I/O errors are reported on all the paths of a LUN including those paths that are not affected by the SANVC node additional and removal and as a result, DMP returns I/O errors back to the upper I/O layers.

Mon May 14 03:13:20.189: I/O error occured on Path hdisk95 belonging to Dmpnode SAN_VC0_86
Mon May 14 03:13:20.190: I/O error occured on Path hdisk5 belonging to Dmpnode SAN_VC0_86
Mon May 14 03:13:20.191: I/O error occured on Path hdisk275 belonging to Dmpnode SAN_VC0_86
Mon May 14 03:13:20.192: I/O error occured on Path hdisk185 belonging to Dmpnode SAN_VC0_86


In another situation the problem may cause DMP to remove all the SANVC DMP devices when "vxdctl enable" is run.

Mar  4 02:19:45 host1 vmunix: NOTICE: VxVM vxdmp V-5-0-111 disabled dmpnode 3/0x20
Mar  4 02:19:45 host1 vmunix: NOTICE: VxVM vxdmp V-5-0-258 removed disk array 020064200b50XX00
Mar  4 02:19:45 host1 vmunix: NOTICE: VxVM vxdmp V-5-0-111 disabled dmpnode 3/0x30

Wed Mar  4 02:19:45.000: Reconfiguration is in progress
Wed Mar  4 02:19:45.000: Reconfiguration has finished

Wed Mar  4 02:19:45.122: Disabled Dmpnode NONAME
Wed Mar  4 02:19:45.122: Disabled Disk array SAN_VC0
Wed Mar  4 02:19:45.122: Disabled Dmpnode NONAME
 

Cause

The problem is caused by a deficiency in the Array Policy Module (APM) in the Veritas Dynamic Multipathing (DMP).   The APM handling the IBM SANVC is named dmpsvc as shown in the vxdmpadm listapm command output.   The SANVC APM module fails to handle the transient errors that occur during the SANVC node addition and removal.


Resolution

The following VxVM versions are ehancement to handle the above reported issue.

Solaris Platform
- 5.0MP1 RP3
- 5.0MP3
- 5.1GA

AIX Platform
- 5.0MP1 RP2
- 5.0MP3
- 5.1GA

Linux Platform
- 5.0MP3
- 5.1GA

HP-UX 11.31 Platform
- 5.1 GA
- The enhancement is not available on the VxVM 5.0 or 5.0.1 versions on the HP-UX 11.31 platforms

Please upgrade to the latest VxVM version to fix the related problems.

Issue/Introduction

Problems can be experienced during IBM SAN Virtual Controller (SANVC/SVC) node addition and removal when running Veritas Volume Manager (VxVM) 5.0.

Additional Information

ETrack: 1037289