Errors V-76-58645-260 and V-39-32775-87 appear after resizing a volume

book

Article ID: 100021269

calendar_today

Updated On:

Description

Error Message

Error V-76-58645-260 and V-39-32775-87

Cause

While the LUN has been changed at the array level, the Operating system is not aware of the changes.  When resizing the LUN, the errors appear due to the resize operation not being aware that the LUN has been expanded.

Resolution

Run a Refresh or Rescan using From Veritas Enterprise Administrator (VEA) -> Actions -> Refresh/Rescan 
 
OR
 
Deport the Diskgroup (DG) and Import it again that contains the volume which is to be resized.
 
 
 
 
 

 

Issue/Introduction

After resizing a LUN from the disk controller interface, which is presented to a Storage Foundation for Windows Host utilizing this LUN for an existing volume, it reports an error.

Additional Information

UMI: V-76-58645-260 UMI: V-39-32775-87