Error V-5-1-530 and V-5-1-10978 reported when attempting to import VxVM diskgroup
book
Article ID: 100021946
calendar_today
Updated On:
Description
Error Message
# vxdg import -fC testdg VxVM vxdg ERROR V-5-1-530 Device testdg not found in configuration
VxVM vxdg ERROR V-5-1-10978 Disk group -fC: import failed:
Not a disk access record
#
Cause
The disk groups that could not be imported being replicated disk groups on a disaster recovery (DR) system possibly had been corrupted due to incomplete replication, preventing Veritas Volume Manager from importing the disk groups, even using the vxdg -fC command.
Resolution
To clear all issues with corruption due to incomplete replication, perform a full resynch for Volume replicator.
After the full synchronization, Volume Manager should be able to import the disk groups without any issues.
Issue/Introduction
When attempting to import a diskgroup on DR site, it would fail with VxVM errors V-5-1-530 and V-5-1-10978
Was this article helpful?
thumb_up
Yes
thumb_down
No