"vxdisk -o thin list" command reports "N/A" for "PHYS_ALLOC" column on XP24k disk array

book

Article ID: 100025173

calendar_today

Updated On:

Description

Error Message

 

 

#vxdisk -o thin list  

  DEVICE          SIZE(mb)     PHYS_ALLOC(mb)  GROUP           TYPE      

xp24k0_0614     103424       N/A             -               thin  

 

Cause

From the Hardware Compatability List (HCL) the xp24k array supports thin reclamation:

"Thin Reclamation is supported with this array; the minimum array firmware 60.06.05-00 is required."

The firmware of the array is also the latest.

The Hardware Compatibility List (HCL) lists Storage Foundation version "5.1, 5.1PR1, 5.1 SP1",  the currently used version 5.1RP1 is not mentioned.

Resolution

Install SF 5.1SP1 instead of 5.1RP1 , the "PHYS_ALLOC" can be correctly displayed.

 

Applies To

SF 5.1RP1 for AIX 6.1

Issue/Introduction