The following EMC CLARiiON devices are presented to a Solaris server using EMC PowerPath as the multipathing solution.
In this instance, the Solaris server is connected to the EMC CLARiiON array with an IP address of "10.12.208.81".

Sample output
Note: The EMC CLARiiON StorageGroup "rdgv240sol13+14-bootdisks" consists of three disks.
# /opt/Navisphere/bin/naviseccli -h 10.12.208.81 storagegroup -list -gname rdgv240sol13+14-bootdisks
Storage Group Name: rdgv240sol13+14-bootdisks
Storage Group UID: 60:CC:49:25:65:41:DF:11:B2:65:00:60:16:01:6D:D5
HBA/SP Pairs:
HBA UID SP Name SPPort
------- ------- ------
10:00:00:01:73:01:BB:EB:20:00:00:01:73:01:BB:EB SP A 1
10:00:00:01:73:01:BB:DF:20:00:00:01:73:01:BB:DF SP A 1
10:00:00:01:73:01:BB:EB:20:00:00:01:73:01:BB:EB SP B 1
10:00:00:01:73:01:BB:DF:20:00:00:01:73:01:BB:DF SP B 1
10:00:00:01:73:01:BB:EB:20:00:00:01:73:01:BB:EB SP A 0
10:00:00:01:73:01:BB:DF:20:00:00:01:73:01:BB:DF SP A 0
10:00:00:01:73:01:BB:EB:20:00:00:01:73:01:BB:EB SP B 0
10:00:00:01:73:01:BB:DF:20:00:00:01:73:01:BB:DF SP B 0
20:00:00:E0:8B:81:29:FA:21:00:00:E0:8B:81:29:FA SP A 0
20:00:00:E0:8B:81:29:FA:21:00:00:E0:8B:81:29:FA SP B 0
20:00:00:E0:8B:81:29:FA:21:00:00:E0:8B:81:29:FA SP A 1
20:00:00:E0:8B:81:29:FA:21:00:00:E0:8B:81:29:FA SP B 1
HLU/ALU Pairs:
HLU Number ALU Number
---------- ----------
5 78
6 79
7 3
Shareable: YES
The "ALU" values reported above can be correlated to the "powermt display dev=all" or "powermt display class=clariion" specifically.
# powermt display class=clariion dev=all
Pseudo name=emcpower3a
CLARiiON ID=CK200053300424 [rdgv240sol13+14-bootdisks]
Logical device ID=60060160E83416001C81C15E575FDF11 [LUN 3] <<< ALU "3"
state=alive; policy=CLAROpt; priority=0; queued-IOs=0
Owner: default=SP B, current=SP B Array failover mode: 4
==============================================================================
---------------- Host --------------- - Stor - -- I/O Path - -- Stats ---
### HW Path I/O Paths Interf. Mode State Q-IOs Errors
==============================================================================
3073 pci@1e,600000/SUNW,jfca@2/fp@0,0 c1t500601603021C60Ed7s0 SP A0 active alive 0 0
3073 pci@1e,600000/SUNW,jfca@2/fp@0,0 c1t500601613021C60Ed7s0 SP A1 active alive 0 0
3073 pci@1e,600000/SUNW,jfca@2/fp@0,0 c1t500601683021C60Ed7s0 SP B0 active alive 0 0
3073 pci@1e,600000/SUNW,jfca@2/fp@0,0 c1t500601693021C60Ed7s0 SP B1 active alive 0 0
3074 pci@1e,600000/SUNW,qlc@3/fp@0,0 c5t500601603021C60Ed7s0 SP A0 active alive 0 0
3074 pci@1e,600000/SUNW,qlc@3/fp@0,0 c5t500601613021C60Ed7s0 SP A1 active alive 0 0
3074 pci@1e,600000/SUNW,qlc@3/fp@0,0 c5t500601683021C60Ed7s0 SP B0 active alive 0 0
3074 pci@1e,600000/SUNW,qlc@3/fp@0,0 c5t500601693021C60Ed7s0 SP B1 active alive 0 0
Pseudo name=emcpower4a
CLARiiON ID=CK200053300424 [rdgv240sol13+14-bootdisks]
Logical device ID=60060160E83416004A3CB095BD3BDE11 [LUN 78] <<< ALU "78"
state=alive; policy=CLAROpt; priority=0; queued-IOs=0
Owner: default=SP B, current=SP B Array failover mode: 4
==============================================================================
---------------- Host --------------- - Stor - -- I/O Path - -- Stats ---
### HW Path I/O Paths Interf. Mode State Q-IOs Errors
==============================================================================
3073 pci@1e,600000/SUNW,jfca@2/fp@0,0 c1t500601603021C60Ed5s0 SP A0 active alive 0 0
3073 pci@1e,600000/SUNW,jfca@2/fp@0,0 c1t500601613021C60Ed5s0 SP A1 active alive 0 0
3073 pci@1e,600000/SUNW,jfca@2/fp@0,0 c1t500601683021C60Ed5s0 SP B0 active alive 0 0
3073 pci@1e,600000/SUNW,jfca@2/fp@0,0 c1t500601693021C60Ed5s0 SP B1 active alive 0 0
3074 pci@1e,600000/SUNW,qlc@3/fp@0,0 c5t500601603021C60Ed5s0 SP A0 active alive 0 0
3074 pci@1e,600000/SUNW,qlc@3/fp@0,0 c5t500601613021C60Ed5s0 SP A1 active alive 0 0
3074 pci@1e,600000/SUNW,qlc@3/fp@0,0 c5t500601683021C60Ed5s0 SP B0 active alive 0 0
3074 pci@1e,600000/SUNW,qlc@3/fp@0,0 c5t500601693021C60Ed5s0 SP B1 active alive 0 0
Pseudo name=emcpower2a
CLARiiON ID=CK200053300424 [rdgv240sol13+14-bootdisks]
Logical device ID=60060160E8341600F2BC89206340DE11 [LUN 79] <<< ALU "79"
state=alive; policy=CLAROpt; priority=0; queued-IOs=0
Owner: default=SP A, current=SP A Array failover mode: 4
==============================================================================
---------------- Host --------------- - Stor - -- I/O Path - -- Stats ---
### HW Path I/O Paths Interf. Mode State Q-IOs Errors
==============================================================================
3073 pci@1e,600000/SUNW,jfca@2/fp@0,0 c1t500601603021C60Ed6s0 SP A0 active alive 0 0
3073 pci@1e,600000/SUNW,jfca@2/fp@0,0 c1t500601613021C60Ed6s0 SP A1 active alive 0 0
3073 pci@1e,600000/SUNW,jfca@2/fp@0,0 c1t500601683021C60Ed6s0 SP B0 active alive 0 0
3073 pci@1e,600000/SUNW,jfca@2/fp@0,0 c1t500601693021C60Ed6s0 SP B1 active alive 0 0
3074 pci@1e,600000/SUNW,qlc@3/fp@0,0 c5t500601603021C60Ed6s0 SP A0 active alive 0 0
3074 pci@1e,600000/SUNW,qlc@3/fp@0,0 c5t500601613021C60Ed6s0 SP A1 active alive 0 0
3074 pci@1e,600000/SUNW,qlc@3/fp@0,0 c5t500601683021C60Ed6s0 SP B0 active alive 0 0
3074 pci@1e,600000/SUNW,qlc@3/fp@0,0 c5t500601693021C60Ed6s0 SP B1 active alive 0 0
Summary
EMC CLARiiON ALU reference "ALU 3" refers to emcpower3
EMC CLARiiON ALU reference "ALU 78" refers to emcpower4
EMC CLARiiON ALU reference "ALU 79" refers to emcpower2
TPD (Third Party Driver)
As of 5.0 MP3 onwards, VxVM/DMP will report the EMC PowerPath (TPD) EMC CLARiiON controlled devices under the PP_EMC_CLARiiON enclosure type.
# vxdmpadm listenclosure all
ENCLR_NAME ENCLR_TYPE ENCLR_SNO STATUS ARRAY_TYPE LUN_COUNT
===================================================================================
disk Disk DISKS CONNECTED Disk 3
pp_emc1 PP_EMC 000290301414 CONNECTED A/A 5
pp_emc_clariion0 PP_EMC_CLARiiON CK200053300424 CONNECTED A/A 3
pp_emc0 PP_EMC 000290300822 CONNECTED A/A 11
Note: As of 5.0 MP3 onwards, DMP will now report a LUN count per enclosure. In this instance there are "3" disks associated with the EMC CLARiiON enclosure.
# powermt display class=clariion
CLARiiON logical device count=3
==============================================================================
----- Host Bus Adapters --------- ------ I/O Paths ----- ------ Stats ------
### HW Path Summary Total Dead IO/Sec Q-IOs Errors
==============================================================================
3073 pci@1e,600000/SUNW,jfca@2/fp@0,0 optimal 12 0 - 0 0
3074 pci@1e,600000/SUNW,qlc@3/fp@0,0 optimal 12 0 - 0 0
# vxdmpadm getctlr all
LNAME PNAME VENDOR CTLR-ID
========================================================================================================
c2 /pci@1c,600000/scsi@2 - -
emcp pseudo - -
# vxdmpadm getportids enclosure=pp_emc_clariion0
NAME ENCLR-NAME ARRAY-PORT-ID pWWN
===================================================================================
emcpower4c pp_emc_clariion0 - -
emcpower2c pp_emc_clariion0 - -
emcpower3 pp_emc_clariion0 - -
Note: The array-port-id and pWWN content is suppressed due to the EMC PowerPath installation.