The following messages are logged in the VCS agent log.
2018/04/07 16:13:01 VCS WARNING V-16-0-13196 Thread(4131375984) script (/opt/VRTSagents/ha/bin/WebSphereMQ/monitor) terminated due to signal (9)
2018/04/07 16:13:01 VCS ERROR V-16-2-13040 Thread(4131375984) Resource(q_mgr_Prod): Program(/opt/VRTSagents/ha/bin/WebSphereMQ/monitor) was abnormally terminated with the exit code(0x9).
This is a Linux kernel issue. The problem can happen to any process with a lengthy program argument list. The problem was reported to occur on the following kernel versions.
2.6.32-642.15.1.el6.x86_64 (RHEL 6.8)
2.6.32-696.el6.x86_64 (RHEL 6.9)
As a temporary workaround please disable the audit rules similar to the ones listed above or disable audit altogether.