Dell Unity OE 5.2 causes Veritas fencing to fail

book

Article ID: 100053670

calendar_today

Updated On:

Description

Error Message

vxfenadm -a -k T1 -f emc_clariion0_47_OE5.2_dmpnode

VXFEN vxfenadm ERROR V-11-2-1215 DMP REGISTER_AND_IGNORE failed for: /dev/vx/rdmp/emc_clariion0_47

VXFEN vxfenadm ERROR V-11-2-1133 Error returned

In system logs, similar messages may be generated while starting vxfen:

- kernel: [ 3482.656204] VXFEN ERROR V-11-1-1 Unable to register with coordinator disk
with serial number: 600601608XXXXXXXXXXXXXXXXXXXXXXX, npaths: 1
VXFEN WARNING V-11-1-50 VxDMP Preempt Abort ioctl failed with error: 6

vxfenconfig ERROR V-11-2-1090 Unable to register with a majority of the coordination points.

Cause

Dell Technologies and Veritas have identified an interoperability issue with new functionality introduced in Unity OE 5.2 related to SCSI-3 Persistent Reservation.  The issue will impact Veritas IO Fencing operations in multipath environments on Unity arrays running Unity OE 5.2.0 and Unity OE 5.2.1.

Resolution

A Unity OE hotfix is available that addresses this issue.  Please contact Dell Technologies and reference the following knowledge article if you want to have the hotfix installed:

https://www.dell.com/support/kbdoc/en-uk/000201773/unity-code-5-2-not-compatible-with-veritas

 

Issue/Introduction

Dell Unity OE 5.2 causes Veritas fencing to fail